News
The Calibration Steps Of Belt Scale
author:admin    Released:2014-07-23 10:14:20

The knowledge about the calibration of belt scale has been mentioned before,and today there are some of the content on the calibration steps of belt scale,then we learn from each other and strive to provide a reference value for the additional purchase of belt scale manufacturer.

 

The calibration procedure of belt scale is as follows:

 

1、In the equipment shutdown condition to carry out the inspection work;

 

2、If there are materials on the conveyor belt,it should clean immediately to ensure the scale body of belt scale clean;

 

3、Check whether the weighing sensor top wire appears loosen the phenomenon,and then check whether the sensor junction box and shaft have materials in contact phenomenon;

 

4、Check whether there is deviation on the conveyor belt,if yes,it should be corrected immediately,and then start running the belt to see whether there is still deviation,until the adjustment to the normal position;

 

5、Adjust the belt control instruments tune into manual mode,the control of transport is set to one hundred percent,begin zero calibration until the error range allowed;

 

6、After calibration instruments,through calibration weights,depending on the range,the weights hanging onto the sensor calibration interval has been calibrated to within tolerance limits.